System Manual

Table Of Contents
Antennas
6.8 ANT 18 (stainless steel variant)
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
233
6GT2398-1DA00
1)
6GT2398-1DA10
Permitted ambient conditions
Ambient temperature
During operation -20 ... +70 °C
During transportation and storage -40 ... +85 °C
Ambient conditions regarding UL approval
for indoor use only (dry location)
Degree of pollution 2
Altitude < 2000 m
Overvoltage category 2
Air humidity < 90 %
Degree of protection according to EN 60529 IP67 with inserted cable
(IP-Rating is not investigated by UL)
Shock-resistant according to EN 60721-3-7 Class
7 M2
3)
500 m/s
2
Vibration-resistant according to EN 60721-3-7
Class 7 M2
3)
200 m/s
2
Design, dimensions and weight
Dimensions (∅ x L)
18 x 40 mm
Thread (∅ x thread x L)
M18 x 1 x 30 mm
Weight without cable/with cable
40 g / 205 g
Type of mounting
2x stainless steel nuts M18 x 1
1)
Investigated by UL
The products 6GT2398-1DA10 and 6GT2398-1DA00 are identical in structure and only differ in the
antenna connecting cable included in the scope of delivery.
2)
The supply source and ext. circuits intended to be connected to this device shall be galv. separat-
ed from mains supply or hazardous live voltage by reinforced or double insulation and meet the
requirements of SELV/PELV circuit of UL/IEC61010-2-201 and clause 9.4 Limited energy circuit of
UL/IEC 61010-1 or Class 2 of NEC or LPS of UL/IEC 60950”.
3)
Warning: The values for shock and vibration are maximum values and must not be applied contin-
uously.