System Manual

Table Of Contents
Antennas
6.9 ANT 30
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
237
6.9.4 Flush-mounted in metal
a
= 20 mm
b
= 20 mm
Figure 6-41 ANT 30 flush-mounted in metal
6.9.5 Minimum spacing
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredic
tably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 23 Minimum distances transponder edge to transponder edge
MDS D124 / MDS D160 /
MDS D324 / MDS D423 /
MDS D424 / MDS D460 /
MDS D524 / MDS D560
MDS D422 / MDS D425 /
MDS D428 / MDS D522 /
MDS D525 / MDS D528 /
MDS D525
MDS D126 / MDS D426 /
MDS D526
RF250R with ANT 30
100 mm
≥ 80 mm
≥ 150 mm