Transponder
7.4 MDS D124
SIMATIC RF200
282 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the
field data results. It is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
7.4.4 Technical specifications
Table 7- 8 Technical specifications for MDS D124
6GT2600-0AC10
Product type designation
SIMATIC MDS D124
Memory
Memory configuration
UID 8 bytes
User memory 112 bytes EEPROM
OTP memory 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Enclosure
Material PPS
Color Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery