System Manual

Table Of Contents
Transponder
7.15 MDS D421
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
339
Installation examples
Figure 7-39 Installation example of MDS D421 in a steep cone
Figure 7-40 Installation example of MDS D421 in a stud bolt
7.15.4 Technical specifications
Table 7- 40 Technical specifications for the MDS D421
6GT2600-4AE00
Product type designation
SIMATIC MDS D421
Memory
Memory configuration
UID 8 bytes
User memory 2000 bytes FRAM
OTP memory 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 39)"
MTBF (Mean Time Between Failures)
228 years