System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Transponder
7.15 MDS D421
SIMATIC RF200
340 System Manual, 03/2019, J31069-D0227-U001-A11-7619
6GT2600-4AE00
Mechanical specifications
Enclosure
• Material • Epoxy resin
• Color • Black
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• during write/read access • -25 … +85 °C
• outside the read/write field • -40 … +100 °C
• during storage • -40 … +100 °C
Degree of protection according to EN 60529
• IP67
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant acc. to EN 60721-3-7, Class 7M2
1)
1000 m/s
2
Vibration-resistant acc. to EN 60721-3-7, Class
7M2
1)
200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
10 x 4.5 mm
Weight
Approx. 1 g
Type of mounting
Glued
2)
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.