- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
39
4.2.1 Field data
The limit distances (S
g
) and operating distances (S
a
) along with the length of the
transmission window for each reader-transponder combination are listed in the tables below.
Table 4- 1 SIMATIC RF210R field data
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
25
1 ... 18
20
MDS D127
1)
3
0 ... 2
2
MDS D160
20
1 ... 10
12
MDS D324
20
1 ... 8
9
MDS D421
5
0 ... 3
4
MDS D422
8
1 ... 9
10
MDS D423
20
2 ... 10
12
MDS D424
24
1 ... 16
18
MDS D425
12
1 ... 6
7
MDS D428
20
1 ... 10
11
MDS D460
8
1 … 8
9
MDS D521
5
0 ... 3
4
MDS D522
8
1 ... 8
9
MDS D522
Special variants
8 1 ... 8 9
MDS D524
20
1 ... 15
17
MDS D525
12
1 ... 6
7
MDS D528
15
1 ... 10
11
MDS D560
8
1 ... 8
9
1)
The transponder is only suitable for static mode.
All dimensions in mm.