System Manual

Table Of Contents
System diagnostics
9.1 Error codes of the RF200 readers
SIMATIC RF200
410 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Table 9- 1 Error codes of the RF200 readers
Flashing of
red LED on
reader
Error code
(hex)
Description
00
0x00
no error
02 0x01 Presence error, possible causes:
The active command was not carried out completely
The transponder left the antenna field while the command was
being processed - communication disruption between reader and
transponder
05 0x05 Parameterization error, possible causes:
Unknown command
Incorrect parameter
Function not allowed
06
0x06
Air interface faulty
12 0x0C The transponder memory cannot be written, possible cause:
Hardware fault (memory faulty)
13 0x0D Error in the specified memory address (access attempted to non-
existent or non-accessible memory areas).
19 0x13 Buffer overflow: Insufficient buffer available in the reader for saving
the command
20
0x14
Major system fault (hardware fault)
21
0x15
Parameter assignment error: faulty parameter in RESET command
24
0x18
Only a RESET command is permitted
25
0x19
Previous command is still active
28
0x1C
Antenna is already switched off/Antenna is already switched on
30
0x1E
Incorrect number of characters in frame
Note
Error message when memory area is protected
For transponders with a locked or protected memory area, different error messages can
occur following a write command depending on the data carrier type, e.g. MDS D1xx (NXP),
D3xx (Infineon), D4xx (Fujitsu): Error 01, 0C