System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
System diagnostics
9.2 Diagnostics functions - STEP 7
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
411
9.2 Diagnostics functions - STEP 7
Further information on RFID diagnostics options can be found in the following function
manuals:
● Function manual Ident profile and Ident blocks
(https://support.industry.siemens.com/cs/us/en/view/106368029)
● Function Manual FB 45 (https://support.industry.siemens.com/cs/ww/en/view/21738808)
9.2.1 Reader diagnostics with "Reader Status" (SLG Status)
With this command you can query the status and diagnostics data of the reader.
Table 9- 2 Attribute "0x81" (mode 01), corresponds to UDT 110
Name
Type
Possible Values
(hex)
Comment
hardware char
0x31
0x32
0x33
0x34
0x41
0x4D
0x4E
Type of hardware
= RF260R
= RF210/220R
= RF240R
= RF250R
= RF290R
= RF280R with RS422
= RF280R with RS232
hardware_version word
0x0100
0x0010; 0x0029; 0x002B;
0x002C
HW version (reserved)
= RF200 without RF280R
= RF280R
loader_version word
0x00 ... 0xFF
0x00 ... 0xFF
Bootstrap loader version: e.g. 3130 (=version 1.0)
= Version (high byte)
= Version (low byte)
firmware
char
0x00 ... 0xFF
FW version : 33 (ASCII : 3 = RF2x0R)
firmware_version word
00 ... FF
00 ... FF
Firmware version: e.g. 3130 (=version 1.0)
= Version (high byte)
= Version (low byte)
driver char
0x31
0x32
0x33
Driver version 3964R
= 3964R
= ASCII
= ASCII/ScanMode
driver_version word
0x00 ... 0xFF
0x00 ... 0xFF
Driver version: e.g. 3132 (=version 1.2)
= Version (high byte)
= Version (low byte)
interface byte
0x01
0x02
Interface type
= RS-422
= RS-232