System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Appendix
A.2 Accessories
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
427
A.2.2.6 Pin assignment of DC outputs and mains connection
Table A- 7 Pin assignment of the DC outputs
Assignment
1
Ground (0 V)
2
+24 VDC
3
+24 VDC
4 Ground (0 V)
Table A- 8 Pin assignment of the mains connector
Assignment
1
PE
2
L (100 … 240 VAC)
3 N (100 … 240 VAC)
A.2.2.7 Technical specifications
Table A- 9 Technical specifications
6GT2898-0ACx0
Product type designation Wide-range power supply unit for SIMATIC RF
systems
Electrical data
Insulation strength (prim./sec.) U
isol p/s
AC 3.3 kV
Primary- secondary side are galvanically isolated
Insulation resistance R
ins
> 1 GΩ
Leakage current I
leak
< 200 µA
at U
in
= 230 VAC, f = 50 Hz
Mains buffering t
h
≥ 50 ms
at U
in
= 230 VAC
Power supply unit classification Level 3
acc. to CSA