System Manual

Table Of Contents
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
45
Table 4- 9 Field data SIMATIC RF250R, with ANT 12 (stainless steel variant)
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D117
3
0 ... 2
3
MDS D127
4
0 ... 3
4
MDS D160
15
0 ... 11
13
MDS D421
9
0 ... 2
3
MDS D422
20
0 ... 5
6
MDS D425
10
1 ... 6
8
MDS D428
16
1 ... 10
12
MDS D460
14
1 ... 8
10
MDS D521
9
0 ... 2
3
MDS D522
9
1 ... 5
7
MDS D522
Special variant
9 1 ... 6 8
MDS D525
10
1 ... 8
10
MDS D528
14
1 ... 10
12
MDS D560
14
1 ... 11
14
All dimensions in mm.
Table 4- 10 Field data SIMATIC RF250R, with ANT 18
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
26
0 ... 24
37
MDS D160
22
1 ... 18
26
MDS D324
30
1 ... 18
27
MDS D421
16
0 ... 3
5
MDS D422
24
1 ... 8
14
MDS D423
21
1 ... 15
18
MDS D424
26
1 ... 27
36
MDS D425
19
1 ... 11
16
MDS D428
19
1 ... 18
25
MDS D460
19
1 ... 17
21
MDS D521
6
0 ... 4
5
MDS D522
15
1 ... 10
12
MDS D522
Special variants
15 1 ... 10 12
MDS D524
30
1 ... 25
30
MDS D525
19
1 ... 11
16
MDS D528
20
1 ... 15
20
MDS D560
19
1 ... 17
21
All dimensions in mm.