System Manual

Table Of Contents
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
46 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Table 4- 11 Field data SIMATIC RF250R, with ANT 18 (stainless steel variant)
Length of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
22
1 ... 28
32
MDS D160
20
1 ... 17
20
MDS D324
28
1 ... 24
27
MDS D421
15
0 ... 3
5
MDS D422
22
0 ... 8
10
MDS D423
21
1 ... 22
25
MDS D424
25
1 ... 30
34
MDS D425
18
1 ... 13
15
MDS D428
18
1 ... 15
18
MDS D460
16
1 ... 15
18
MDS D521
5
0 ... 3
5
MDS D522
14
1 ... 10
12
MDS D522
Special variant
12 1 ... 7 9
MDS D524
30
1 ... 26
30
MDS D525
18
1 ... 13
16
MDS D528
18
1 ... 17
20
MDS D560
18
1 ... 17
21
All dimensions in mm.