System Manual

Table Of Contents
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
50 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Table 4- 15 Field data SIMATIC RF280R
Length of the transmission window
(L)
Operating distance
(S
a
)
Limit distance (S
g
)
in the x direction
(L
x
)
in the y direction
(L
y
)
MDS D100
1)
140
100
10 ... 160
200
MDS D124
80
80
2 ... 110
130
MDS D126
180
140
2 ... 135
160
MDS D139
140
90
5 ... 150
190
MDS D160
80
40
2 ... 55
70
MDS D165
1)
200
140
10 ... 160
190
MDS D200
2)
200
160
20 ... 140
185
MDS D261
3)
190
120
20 ... 110
150
MDS D324
100
60
2 ... 85
110
MDS D339
290
140
5 ... 150
170
MDS D400
240
120
10 ... 170
200
MDS D423
110
60
5 ... 60
70
MDS D424
100
70
2 ... 100
140
MDS D425
80
45
2 ... 30
40
MDS D426
220
160
2 ... 145
175
MDS D428
80
50
2 ... 60
88
MDS D460
80
70
2 ... 55
70
MDS D524
100
70
2 ... 110
130
MDS D525
80
45
2 ... 30
40
MDS D526
220
160
2 ... 135
165
MDS D528
80
50
2 ... 60
85
MDS D560
80
70
2 ... 55
70
All dimensions in mm.
1)
Be aware that the minimum distance must be increased 10 mm starting at 40 °C ambient tempera-
ture.
2)
Be aware that the minimum distance of the reader to the transponder must be increased approxi-
mately 6 mm every 5 °C starting at an ambient temperature of 25 °C and approximately 15 mm
starting at an ambient temperature of 50 °C.
3)
Be aware that the minimum distance of the reader to the transponder must be increased approxi-
mately 3 mm every 5 °C starting at an ambient temperature of 25 °C and approximately 14 mm
starting at an ambient temperature of 50 °C.