System Manual

Table Of Contents
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
51
Table 4- 16 Field data SIMATIC RF285R, with ANT D1
Length of the transmis-
sion window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D100
150
10 ... 150
200
MDS D124
60
0 ... 100
140
MDS D126
150
5 ... 110
150
MDS D139
110
5 ... 160
220
MDS D160
50
0 ... 65
90
MDS D165
150
10 ... 150
200
MDS D200
150
10 ... 130
180
MDS D261
120
5 ... 130
180
MDS D324
50
0 ... 90
130
MDS D339
110
5 ... 130
170
MDS D400
150
10 ... 130
180
MDS D423
50
10 ... 60
85
MDS D424
60
0 ... 90
130
MDS D426
110
5 ... 100
140
MDS D428
60
0 ... 55
80
MDS D460
50
0 ... 60
85
MDS D524
60
0 ... 90
130
MDS D526
110
5 ... 100
140
MDS D528
60
0 ... 55
80
MDS D560
50
0 ... 60
85
All dimensions in mm.