- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Planning the RF200 system
4.2 Field data of transponders and readers
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
57
Table 4- 24 Minimum clearances for transponders - Part 2
RF250R
1)
ANT 1
ANT 3 /
ANT 30
ANT 3S /
ANT 18
ANT 8
ANT 12
MDS D100
≥ 300
--
--
--
--
MDS D117
--
--
--
≥ 30
≥ 50
MDS D124
≥ 200
≥ 100
≥ 80
--
--
MDS D126
≥ 250
≥ 100
--
--
--
MDS D127
--
--
--
≥ 40
≥ 60
MDS D139
≥ 300
--
--
--
--
MDS D160
≥ 200
≥ 100
≥ 80
--
≥ 60
MDS D165
≥ 300
--
--
--
--
MDS D200
≥ 300
--
--
--
--
MDS D261
≥ 300
--
--
--
--
MDS D324
≥ 200
≥ 100
≥ 80
--
--
MDS D339
≥ 300
--
--
--
--
MDS D400
≥ 300
--
--
--
--
MDS D421
--
--
≥ 50
≥ 30
≥ 40
MDS D422
--
≥ 70
≥ 60
--
≥ 50
MDS D423
≥ 200
≥ 100
≥ 80
--
--
MDS D424
≥ 200
≥ 100
≥ 80
--
--
MDS D425
≥ 150
≥ 80
≥ 60
--
≥ 50
MDS D426
≥ 250
≥ 100
--
--
--
MDS D428
≥ 150
≥ 80
≥ 60
--
≥ 50
MDS D460
≥ 200
≥ 100
≥ 80
--
≥ 60
MDS D521
--
--
≥ 50
≥ 30
≥ 40
MDS D522
--
≥ 70
≥ 60
--
≥ 50
MDS D522
Special variant
-- ≥ 70 ≥ 60 -- ≥ 50
MDS D524
≥ 200
≥ 100
≥ 80
--
--
MDS D525
≥ 150
≥ 80
≥ 60
--
≥ 50
MDS D526
≥ 250
≥ 100
--
--
--
MDS D528
≥ 150
≥ 80
≥ 60
--
≥ 50
MDS D560
≥ 200
≥ 100
≥ 80
--
≥ 60
1)
Depends on the connected antenna.
All values are in mm, relative to the operating distance (S
a
) between reader and transponder, and
between transponder edge and transponder edge