Table 4- 38 Reduction of field data due to metal, range as %: Transponder and RF250R with ANT 3S
Transponder
RF250R with ANT 3S
Antenna without
metal
Antenna flush-
mounted in metal
MDS D117
Flush-mounted in metal;
distance all round 20 mm
100 90
MDS D127
Flush-mounted in metal;
distance all round 20 mm
100 90
MDS D421
Flush-mounted in metal;
distance all round 20 mm
100 90
MDS D521
Flush-mounted in metal;
distance all round 20 mm
100 90
Table 4- 39 Reduction of field data due to metal, range as %: Transponder and RF250R with ANT 8
Transponder
RF250R with ANT 8
Antenna without
metal
Antenna flush-
mounted in metal
MDS D117
Without metal
100
85
Flush-mounted in metal;
distance all round 0 mm
65 55
MDS D127
Without metal
100
85
Flush-mounted in metal;
distance all round 0 mm
70 60
MDS D421
Without metal
100
85
Flush-mounted in metal;
distance all round 0 mm
75 70
MDS D521
Without metal
100
85
Flush-mounted in metal;
distance all round 0 mm
75 70