System Manual

Table Of Contents
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
84 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Table 4- 44 Reduction of field data due to metal, range as %: Transponder and RF280R
Transponder
Reader without
metal direct
metal influence
Reader on
metal (metal
plate)
Flush-mounted
in metal (20 mm
all-round)
MDS D100
1)
Without metal
100
95
80
On metal; distance 20 mm
65
60
55
Flush-mounted in metal;
distance all round 20 mm
2)
55 50 45
MDS D124
1)
Without metal
100
95
90
On metal; distance 15 mm
95
90
85
Flush-mounted in metal;
distance all round 20 mm
2)
70 65 50
MDS D126
1)
Without metal
100
90
80
On metal; distance 25 mm
80
75
70
Flush-mounted in metal;
distance all round 50 mm
3)
75 65 65
MDS D139
1)
Without metal
100
90
75
On metal; distance 30 mm
95
85
70
Flush-mounted in metal;
distance all round 100 mm
4)
90 80 70
MDS D160
1)
Without metal
100
95
90
On metal; distance 10 mm
2)
85
85
80
MDS D165
Without metal
100
90
80
On metal; distance 25 mm
4)
80
75
70
MDS D200
1)
Without metal
100
90
80
On metal; distance 20 mm
80
75
70
Flush-mounted in metal;
distance all round 20 mm
3)
65 60 55
MDS D261
Without metal
100
95
85
On metal; distance 25 mm
4)
85
80
75
MDS D324
1)
Without metal
100
95
85
On metal; distance 15 mm
85
85
80
Flush-mounted in metal;
distance all round 25 mm
2)
70 65 60
MDS D339
1)
Without metal
100
90
80
On metal; distance 30 mm
85
80
75
Flush-mounted in metal;
distance all round 100 mm
4)
80 75 70
MDS D400
1)
Without metal
100
90
80
On metal; distance 20 mm
75
70
60
Flush-mounted in metal;
distance all round 20 mm
4)
60 60 55