System Manual

Table Of Contents
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
89
Transponder
RF285R with ANT D5
Antenna on metal
(metal plate)
Antenna flush-
mounted in metal
(all round 150 mm)
MDS D165
Without metal
100
95
On metal, distance 25 mm
65
60
MDS D200
1)
Without metal
100
95
On metal, distance 20 mm
65
60
Flush-mounted in metal;
distance all round 20 mm
45 40
MDS D261
Without metal
100
95
On metal, distance 25 mm
65
60
MDS D324
1)
Without metal
100
95
On metal, distance 15 mm
75
70
MDS D339
1)
Without metal
100
95
On metal, distance 30 mm
90
85
MDS D400
1)
Without metal
100
95
On metal, distance 20 mm
65
60
Flush-mounted in metal;
distance all round 20 mm
45 40
MDS D424
1)
Without metal
100
95
On metal, distance 15 mm
75
70
MDS D426
1)
Without metal
100
95
On metal, distance 25 mm
70
65
Flush-mounted in metal;
distance all round 50 mm
50 45
MDS D460
1)
Without metal
100
95
On metal, distance 10 mm
70
65
MDS D560
1)
Without metal
100
95
On metal, distance 10 mm
70
65
1)
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
adequate clearance to the metal.