92 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Table 4- 48 Reduction of field data due to metal, range as %: Transponder and RF290R with ANT
D1
Transponder
Antenna without
metal
Antenna on
metal
Antenna flush-
mounted in
metal
(all round 30
mm)
MDS D100
1)
Without metal
100
85
80
On metal; distance 20 mm
70
60
65
Flush-mounted in metal;
distance all round 20 mm
60 45 45
MDS D124
1)
Without metal
100
95
85
On metal; distance 15 mm
85
85
80
Flush-mounted in metal;
distance all round 20 mm
85 80 50
MDS D126
1)
Without metal
100
85
85
On metal; distance 25 mm
85
75
75
Flush-mounted in metal;
distance all round 50 mm
80 70 70
MDS D139
1)
Without metal
100
90
85
On metal; distance 30 mm
95
85
85
Flush-mounted in metal;
distance all round 100 mm
95 85 85
MDS D160
1)
Without metal
100
95
90
On metal; distance 10 mm
85
85
80
MDS D165
Without metal
100
85
85
On metal; distance 25 mm
90
80
75
MDS D200
1)
Without metal
100
85
80
On metal; distance 20 mm
85
75
75
Flush-mounted in metal;
distance all round 20 mm
75 65 65
MDS D261
Without metal
100
90
85
On metal; distance 25 mm
85
80
80
MDS D324
1)
Without metal
100
85
85
On metal; distance 15 mm
90
80
80
Flush-mounted in metal;
distance all round 25 mm
80 75 65
MDS D339
1)
Without metal
100
90
85
On metal; distance 30 mm
95
85
85
Flush-mounted in metal;
distance all round 100 mm
95 85 85
MDS D400
1)
Without metal
100
90
85
On metal; distance 20 mm
80
70
65
Flush-mounted in metal;
distance all round 20 mm
65 60 60