System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
95
Transponder
RF290R with ANT D5
Antenna on metal
(metal plate)
Antenna flush-
mounted in metal
(all round 150 mm)
MDS D460
1)
Without metal
100
95
On metal, distance 10 mm
70
65
MDS D524
1)
Without metal
100
95
On metal, distance 15 mm
75
70
MDS D526
1)
Without metal
100
95
On metal, distance 25 mm
70
65
Flush-mounted in metal;
distance all round 50 mm
50 45
MDS D560
1)
Without metal
100
95
On metal, distance 10 mm
70
65
1)
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
adequate clearance to the metal.
Table 4- 50 Reduction of field data due to metal, range as %: Transponder and RF290R with ANT
D6
Transponder
RF290R with ANT D6
Antenna on metal
(metal plate)
Antenna flush-
mounted in metal
(all round 200 mm)
MDS D100
1)
Without metal
100
95
On metal, distance 20 mm
65
60
MDS D124
1)
Without metal
100
95
On metal, distance 25 mm
80
75
MDS D126
1)
Without metal
100
95
On metal, distance 25 mm
65
60
MDS D139
1)
Without metal
100
90
On metal, distance 30 mm
80
70
MDS D160
1)
Without metal
100
90
On metal, distance 25 mm
60
55
MDS D165
Without metal
100
95
On metal, distance 20 mm
50
45
MDS D200
1)
Without metal
100
95
On metal, distance 20 mm
65
60
MDS D261
Without metal
100
95
On metal, distance 20 mm
50
45
MDS D324
1)
Without metal
100
95
On metal, distance 25 mm
75
70