RFID Systems SIMATIC RF310M Mobile Reader Operating Instructions · 07/2007 SIMATIC RF310M Mobile Reader simatic sensors DOCUMENTATION
SIMATIC Sensors RFID Systems SIMATIC RF310M Mobile Reader Operating Instructions Introduction 1 Description 2 Power supply 3 Commissioning 4 Operation 5 SIMATIC RF310M software 6 Advanced functions 7 Error messages of the SIMATIC RF310M application Troubleshooting Technical Specifications Appendix 07/2007 J31069-D0191-U001-A1-7618 8 9 10 A
Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken.
Table of contents 1 Introduction................................................................................................................................................ 7 2 Description................................................................................................................................................. 9 3 4 5 6 2.1 Application area .............................................................................................................................9 2.
Table of contents 7 6.5.4 6.5.5 6.5.6 6.5.7 6.5.8 6.5.9 6.5.10 Read OTP ................................................................................................................................... 35 Reading the tag configuration data ............................................................................................. 36 Writing to the tag ......................................................................................................................... 37 Write OTP.................
1 Introduction Purpose of this document These operating instructions contain information required for starting up and using the RF310M device. The documentation is aimed at commissioning engineers and machine operators who start up the application themselves, and it describes the functions of the "SIMATIC RF310M" software. Scope of validity of this document This documentation is valid for the SIMATIC RF310M Mobile Reader and describes the delivery status from July 2007.
Introduction 8 SIMATIC RF310M Mobile Reader Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
Description 2 SIMATIC RF310M expands the RF300 RF identification system with a powerful mobile handheld reader for applications in the areas of production and service. In addition, it is an indispensable aid for startup and testing. 2.1 Application area The RF300 Mobile Reader is intended especially for the SIMATIC RF300 RFID system. The enclosed SIMATIC RF310M software allows user-friendly, distributed reading and writing of all RF300 tags. The Mobile Reader can also be used in harsh environments.
Description 2.2 Features 2.2 Features The SIMATIC RF310M Mobile Reader consists of a powerful, rugged and flexible handheld computer (PSION WORKABOUT PRO) and an integral read/write unit for the SIMATIC RF300 RFID system. It meets the requirements of mobile RFID data acquisition in harsh environments in an extremely user-friendly and ergonomic design. Based on communications standards, the device guarantees simple integration into existing or planned infrastructure.
Description 2.3 Design 2.3 Design The RF300 Mobile Reader consists of a basic unit and an integral read/write head (①) of the SIMATIC RF300. The basic unit is a PSION Workabout PRO and represents a global standard among mobile readers. The SIMATIC RF310M software is stored in an integral flash disk secure against power failure. The program launches automatically when the Mobile Reader is switched on.
Description 2.4 Antenna and antenna field 2.4 Antenna and antenna field Read head with integral antenna The antenna is housed in the read head ① under a cover. Figure 2-1 Read head with antenna Direction of propagation of the high-frequency field The read/write area for transponders is above and below the front part of the housing. Transponders cannot be read or written to from the end. The figure below shows the direction of propagation of the HF field of the antenna.
3 Power supply 3.1 Inserting the battery The Mobile Reader's battery is located on the rear of the unit. Steps for inserting the battery 1. Use the other end of the input pen as a screwdriver: 2. Turn the screws counter-clockwise. 3. To remove the cover, lift the screw side first. 4. Hold the battery at an angle when inserting so that the side of the battery with the direction arrow is inserted into the battery compartment first.
Power supply 3.2 Charging function 3.2 Charging function Complete charging of an empty battery takes approximately 5 hours. Starting the charging operation The charging operation is started as soon as you insert the PSION Workabout Pro into the charging cradle. WARNING Explosion hazard when using a different charging cradle. Use only the original charging cradle from PSION. Use of another charging station can result in explosions and serious personal injury.
Power supply 3.3 Using other batteries 3.3 Using other batteries Other AA batteries can be used in the PSION Workabout Pro . These can be rechargeable lithium ion batteries or non-rechargeable alkaline batteries. CAUTION Information in the PSION manual concerning the use of other batteries When using other batteries, please note the information in the PSION User Manual! Unsuitable batteries can result in damage. 3.
Power supply 3.
4 Commissioning 4.1 Scope of supply The scope of supply of the RF310M comprises several components. Ordered components Order No.
Commissioning 4.2 Switching on the device 4.2 Switching on the device Requirements for startup ● The Mobile Reader SIMATIC RF310M is ready-mounted ● The unit's battery is charged (see Charging function (Page 14)). Note Before switching the device on for the first time, you must insert the Mobile Reader into the charging cradle and charge it for approximately 5 hours. Switching on the device To switch the Mobile Reader on, press and hold the red "ENTER ON" button for at least one second.
Commissioning 4.3 Basic settings 4.3 Basic settings 4.3.1 Setting the language You can set the following menu languages for operating the Mobile Reader SIMATIC RF310M: ● English ● German Procedure for selecting the language Select the desired language in the "Language selection" window of the "Extras > Language" menu and confirm with "OK".
Commissioning 4.3 Basic settings 4.3.2 Adjusting the acoustic signal volume The tag functions trigger an acoustic signal indicating whether the operations were successful or were terminated with an error. You can switch these acoustic acknowledgements/signals on and off and you can regulate their volume. Adjusting the volume of the acoustic signals 1. Press the blue key twice in succession so that "BLUE KEY" appears on the right of the display. 2.
5 Operation 5.1 The keypad 5.1.1 The shift keys Pressing a shift key causes a change in the function of the subsequently pressed keys.
Operation 5.1 The keypad 5.1.
Operation 5.1 The keypad Key functions Table 5-1 Item ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ Key functions Key Designation Function Arrow keys Enable navigation to the left, right, up and down in the display. Closes the currently open menu, dialog window or started application and leads back to the previous interface. Shift key: Changes the function of other keys Inserting spaces.
Operation 5.2 The SIMATIC RF310M menu 5.2 The SIMATIC RF310M menu The menu bar of the SIMATIC RF310M program comprises five main menus: ● File ● Tag ● Editor ● Extras ● ? The functions of the individual menus can be selected with the help of the shortcuts [see Overview of functions (Page 25) ] or via the touchscreen (with input pen). Press together with the underlined letter in the menu in each case for the relevant shortcut.
6 SIMATIC RF310M software 6.1 Overview of functions After switching on the Mobile Reader, the Editor appears on the display. You can now view the data, enter new data or call a function via the menu.
SIMATIC RF310M software 6.2 Starting the SIMATIC RF310M software 6.2 Starting the SIMATIC RF310M software If the SIMATIC RF310M software is not started when the device is switched on, it can be started using the "RF310M" icon on the desktop or via "Desktop > My Computer > Flash Disk > RF310M". 6.3 The data editor The transponder data (MDS data) can be edited in the editor window in hex or ASCII format. You can toggle between the two in the Editor/Display menu.
SIMATIC RF310M software 6.3 The data editor Interface structure of the data editor Interface Item Description ① MDS type or MDS size ② Data field The data at which the cursor is located is represented alternatively in the formats hexadecimal, decimal, ASCII or binary. The data field can be modified with the Data Edit (Page 42) function. ③ The editor window contains the MDS data. The size of the represented data depends on the MDS type.
SIMATIC RF310M software 6.4 The functions in the "File" menu 6.4 The functions in the "File" menu The following file functions are available that you can select in the menu via "Tag" (or ): ● Load ● Save ● Exit Figure 6-2 6.4.
SIMATIC RF310M software 6.4 The functions in the "File" menu 6.4.3 Exit You can exit the SIMATIC RF310M program using "File > Exit" (or ) or the key. You then reach the WinCE operating system level of the PSION Workabout Pro. You require the password relevant to the application for this, if you have previously assigned one.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5 The functions in the "Tag" menu The following tag functions are available that you can select in the menu via "Tag" (or ): ● Read ● Read OTP ● Read Config.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.1 Progress and timeout display The tag (MDS) functions carry out communication with the transponder. They indicate the progress of the currently executing function and any timeout, if applicable: Progress display in the case of the tag function During data transfer, the progress of the executing function is displayed as a percentage, e.g.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.2 Requirements for operating the tag functions To enable execution of the tag functions, you must set the memory size of the tag and the minimum distances between the Mobile Reader and the tag. Setting the memory size of the tag (Tag Type Selection) Set the memory size of the tag using "Extras" > "Tag Type Selection" ( or ). See also Tag Type Selection (Page 46).
SIMATIC RF310M software 6.5 The functions in the "Tag" menu NOTICE Avoid several tags in the field of the SIMATIC RF310M Please ensure that when executing the tag functions, the minimum distances from transponders are observed, that is, distances between 100 and 500 mm depending on the tag type. (See the System Manual SIMATIC RF300 > RF300 planning the system > Field data of transponders, readers and antennas).
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.3 Read tag (MDS) Note Distance limits between the tag and the Mobile Reader Please observe the maximum distance limits between the Mobile Reader and the tag when reading a tag. See Read/write distances between the Mobile Reader and the RF300 tag (Page 32) Reading the data area of a tag Using "Tag > Read" ( or ), you can read from the tag a data area with a freely definable start and end address.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu Read complete tag When reading an RFID tag, the entire tag is read if you select the setting "Complete Tag" under Read / Write in the "Address Setup" window of "Extras" > "Address Setup> (): Figure 6-8 "Address Setup" settings for reading the complete tag This setting remains in force for all further read/write operations until the values are changed again. See also Address Setup (Page 45). 6.5.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.5 Reading the tag configuration data You can execute reading of the configuration data of a tag using the menu command "Tag > Read Config. Data" (or ), if you keep the tag at the minimum distance from the read head of the Mobile Reader.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.6 Writing to the tag Using "Tag > Write" ( or ), you can write to a tag that is at a sufficient distance from the Mobile Reader. In the "Write Tag" window, enter the "Start Address" and "Length" of the write area and confirm with .
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.7 Write OTP CAUTION The "Write OTP" key is non-reversible. Please note that the OTP memory area can only be written to once. It is not possible to change the values in the OTP area of a tag at a later time. Using "Tag > Write OTP" (or ), you can write once to the OTP area of a tag that is at a sufficient distance from the Mobile Reader.
SIMATIC RF310M software 6.5 The functions in the "Tag" menu 6.5.8 Read tag status You can read and display the status data of the transponder using "Tag > MDS Status" (or ). The following tag status information is displayed here: ● Tag ID (8-character hexadecimal representation) ● Tag memory size (20 bytes EEPROM, 8KB FRAM , 32KB FRAM, 64KB FRAM) ● Status of the lock-bit register (write-protection status) in hexadecimal representation ● Field strength ● ASIC vers. Figure 6-10 6.5.
SIMATIC RF310M software 6.6 The functions in the "Editor" menu 6.6 The functions in the "Editor" menu The following Editor functions are available that you can select in the menu via "Editor" (or ): ● Jump to Address ● Display ● Clear ● Data Edit Figure 6-11 6.6.1 The Editor functions Jump to Address You can enter a memory address in decimal or hexadecimal format using "Editor > Jump to Address" (or ). This address will then be set as the start address in the Editor.
SIMATIC RF310M software 6.6 The functions in the "Editor" menu 6.6.2 Display You can make the following settings in the "Display" menu (or ): ● Toggling the Editor between "Hex" and "ASCII" representation. ● Toggling the data between "Hex", "Dec", "ASCII" and "Bin" representation. ● Toggling addresses between "Dec" and "Hex" representation. Figure 6-12 6.6.
SIMATIC RF310M software 6.6 The functions in the "Editor" menu 6.6.4 Data Edit There are two ways of modifying the values of a memory cell in the display: ● Select the relevant cell direct via the touchscreen and enter the desired value using the keypad. ● Select "Editor > Data Edit" (or ) to enter the desired value in the "Data Edit" window. Figure 6-14 Data Edit The value is entered in the cell at which the cursor is currently located.
SIMATIC RF310M software 6.7 The functions in the "Extras" menu 6.
SIMATIC RF310M software 6.7 The functions in the "Extras" menu 6.7.1 Password You can assign an optional password. Select "Extras > Password" (or ). Figure 6-16 Password change Enter a password with up to 8 characters under "New Password". The password is queried before a write function. An entered password remains valid until the Mobile Reader is switched off. This means you only have to enter the password once in the case of several consecutive write commands.
SIMATIC RF310M software 6.7 The functions in the "Extras" menu 6.7.3 Address Setup The Address Setup function defines the call of the commands "Read/Write MDS". Select "Extras > Address Setup" (or ) for this purpose. The following window appears: Figure 6-17 Address Setup "Start Address and" Under "Read / Write", you can choose the parameters "Length" and "End Address".
SIMATIC RF310M software 6.7 The functions in the "Extras" menu 6.7.4 Tag Type Selection Figure 6-18 Tag Type Selection Memory size of the tag to be edited Set the memory size of the tag using "Extras" > "Tag Type Selection" (or ). Possible settings: ● 20-byte EEPROM ● 8K Byte FRAM ● 32K Byte FRAM ● 64K Byte FRAM This setting also defines the memory area in the editor. It is not possible to access tag memory addresses beyond the memory size.
SIMATIC RF310M software 6.7 The functions in the "Extras" menu 6.7.5 SLG Status Versions statuses and settings of the RF300 read/write device can be read out with the function SLG Status ().
SIMATIC RF310M software 6.8 The functions in the "?" menu 6.
Advanced functions 7.1 7 File storage on the RF310M The data read from the tag are automatically stored on the Mobile Reader to a file with the name "READ_RF300.HEX" in the "Flash Disk" folder. Every subsequent read command overwrites this file. When writing to the tag, the write data are written from the Editor to the tag and also to the "Flash Disk" folder of the Mobile Reader under the name "WRITE_RF300.HEX". Every subsequent write command overwrites this file.
Advanced functions 7.2 Copying data from and to the Mobile Reader 7.2 Copying data from and to the Mobile Reader 7.2.1 Prerequisites ● USB driver for the PSION Workabout Pro. ● The ActiveSync program from Microsoft ● A USB cable for connecting the PC to the PSION Workabout PRO . (Included in the scope of supply of the docking station.
Advanced functions 7.2 Copying data from and to the Mobile Reader 7.2.2 Working with the Active Sync program The ActiveSync program provides a connection via the USB to PSION Workabout Pro . You can now copy data and programs very easily in the manner familiar from Explorer. You only have to select the point "Mobile Device" in Explorer. It is also possible to reach the Workabout PRO directly via ActiveSync .
Advanced functions 7.2 Copying data from and to the Mobile Reader Opening the PSION workstation via ActiveSync and "Explore": Select the "Explore" button (on installation, this appears as the German: "Durchsuchen") in order to reach the Workabout PRO device via ActiveSync . Figure 7-2 Access to Workabout PRO via Active Sync "Explore" Then select the "Flash Disk" folder.
Advanced functions 7.2 Copying data from and to the Mobile Reader Opening the PSION workstation/"Flash Disk" folder Open the "Flash Disk" folder. Figure 7-4 Flash disk folder There you will find the file "READ_RF310.hex" and the files you have stored with the extension ".hex". You can now drag and drop or copy these files from the drive of the PSION Workabout Pro to the PC drive. The file READ or WRITE has a length that corresponds to the size of the read MDS: READ_RF310.
Advanced functions 7.3 The automatic power-saving function 7.3 The automatic power-saving function The PSION Workabout Pro has an automatic shutdown function. This is activated if no key on the Mobile Reader is pressed for approximately 5 minutes. In addition, the "SIMATIC RF310M" software has a further power-saving function.
Error messages of the SIMATIC RF310M application 8 The messages in the table below can occur during operation. They are displayed in a separate window. An error message can appear as follows: Figure 8-1 Typical error message The first number designates the interface function with which the error occurred. The second number provides more detailed information about the error. The meanings of the numbers are explained in the subsequent text (always in English).
Error messages of the SIMATIC RF310M application General errors General errors communicated by the read/write device are displayed as error code 101 to 131. These errors can occur with all functions.
Error messages of the SIMATIC RF310M application Read StartProtocol - 2 Interface function Error code Error message/display Meaning 2 1 invalid parameter Invalid parameters 2 2 timeout; reader send no start protocol; reader not connected No communication to the reader: Hardware missing or defective 2 3 user abort Abort by user 2 4 BCC error BCC error 2 9 unknown error Unknown system error Read/Write Data Command - 80, 81 Interface function Error code Error message/display Meaning
Error messages of the SIMATIC RF310M application Reset Command - 83 Interface function Error code Error message/display Meaning 83 5 error, wrong standbyTime Incorrect parameter: StandbyTime 83 6 error, wrong Distance Limit Incorrect parameter: Distance Limit 83 40 error during request Error when sending the command 83 41 error during read answer Error when receiving command 83 42 no answer from tag/ no tag in field No reply from tag/no tag in the field 83 43 user abort Abort by
Error messages of the SIMATIC RF310M application Read SLG Status Command - 86 Interface function Error code Error message/display Meaning 86 40 error during request Error when sending the command 86 41 error during read answer Error when receiving command 86 41 no answer from tag/ no tag in field No reply from tag/no tag in the field 86 43 user abort Abort by user 86 45 error, answer not ok Error in command response 86 255 no tag in field No tag in field SIMATIC RF310M Mobile Re
Error messages of the SIMATIC RF310M application 60 SIMATIC RF310M Mobile Reader Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
9 Troubleshooting Problem Possible cause Problem recovery The display goes blank when reading/writing. The battery or the batteries of the Mobile Reader are empty. Insert the device into the charging and docking station or insert new batteries. The display is blank after switching on. The battery or the batteries are empty. Insert the device into the charging and docking station or insert new batteries. Error messages appear that are not defined anywhere.
Troubleshooting 62 SIMATIC RF310M Mobile Reader Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
10 Technical Specifications Processor Intel Xscale PXA 255 - 400 MHz, ARM RAM 128 MB ROM 32 MB Flash ROM User program RF310M.exe Screen Color touch display, 320x240 vertical format Keypad Alphanumerical Sound Piezo signal transmitter Power supply Lithium-ion battery (3.
Technical Specifications 64 SIMATIC RF310M Mobile Reader Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
A Appendix A.1 FCC information Siemens SIMATIC RF310M FCC ID NXW-RF310M01 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Appendix A.3 Ordering components for advanced functions A.3 Ordering components for advanced functions The advanced functions of the SIMATIC RF310M Mobile Reader, require components that are not supplied by Siemens. If you require these components for your application, please contact PSION direct or its representative in your country. You can find addresses and order lists for PSION on the Internet at www.psionteklogix.
Appendix A.5 ASCII table A.
Appendix A.6 Service and support A.6 Service and support Technical Support You can reach the technical support team for all A&D projects at ● Telephone: +49 (0) 180 5050 222 ● Fax: +49 (0) 180 5050 223 Internet ● You can contact us via the Internet at: http://www.siemens.com/automation/service&support ● We would be only too pleased to respond to any support queries at: http://www.siemens.
Appendix A.8 Training A.8 Training Training center We offer appropriate courses to get you started. Please contact your local Training Center or the Central Training Center in D-90327 Nuremberg. Telephone: +49 (911) 895-3200 http://www.siemens.
Appendix A.
Glossary Byte A group of eight bits form a byte.
Glossary Readers Readers ensure fast, secure data transfer between mobile data storage units and higherlevel systems. The data, energy included, are transmitted across an electromagnetic alternating field. This principle enables contact-free data transmission, ensures high industrial compatibility and works reliably in the presence of contamination or through nonmetallic materials.
Index A Accessories, 10, 65 ActiveSync, 52 Address, 40 Address Setup, 45 Application area, 9 ASCII table, 67 Automatic shutdown, 18 B Backlighting, 20 Backup battery, 15 Battery Charging, 14 Inserting, 13 Level of charge, 14 C Charging Battery, 14 Clear, 41 Configuration data Read, 36 Contacts, 68 Conventions, 7 Current area, 27 D Data Edit, 42 Data editor Interface structure, 27 Delivery status Restoring, 54 Design, 11 Directories, 49 Display, 41 Progress, 31 Setting, 41 SIMATIC RF310M Mobile Reader Op
Index J READ_x.HEX, 53 Jump to Address, 40 S K Key combinations, 25 Key functions, 23 Keypad Overview, 22 L Language selection, 19, 44 LED Charge indicator, 11 Read head, function indicator, 11 Length, 45 Level of charge, 14 O Open via Mobile Device, 51 via PSION workstation, 51 Order No.
Siemens AG Automation and Drives Factory Automation Sensors Postfach 4848 90327 NÜRNBERG DEUTSCHLAND www.siemens.