System Manual

ISO transponder
8.13 MDS D339
SIMATIC RF300
328 System Manual, 07/2017, C79000-G8976-C345-07
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with
metal screws (M5). This has no tangible impact on the range. It is
recommended that a test is performed in critical applications.
8.13.4
Cleaning the mobile data memory
Note
Do not clean the transponder with mechanical tools, sand
-blasting or pressure hose. These
cleaning methods result in damage to the transponder.
Clean the transponder only with the cleaning agents listed in the section "Chemical
resistance of the MDS".
8.13.5
Technical specifications
Table 8- 33 Technical specifications of MDS D339
6GT2600-3AA10
Product type designation
Memory
Memory configuration
UID 8 bytes
User memory 992 bytes EEPROM
OTP memory 16 bytes (EEPROM)
Read cycles (at < 40 ℃) > 10
14
Write cycles (at < 40 ℃) > 10
6
Data retention time (at < 40 ℃)
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Material PPS