User's Manual Part 1
Table Of Contents
- Titel
- SIMATIC Sensors RFID systems SIMATIC RF300
- Legal Information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 RF300 system planning
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader (with IQ-Sense interface) and transponder
- 4.1.9 Calculation example (IQ-Sense)
- 4.1.10 Communication between communication module, reader (with RS422 interface) and transponder
- 4.1.11 Calculation example (RS422)
- 4.2 Field data for transponders, readers and antennas
- 4.3 Relationship between the volume of data and the transponder speed
- 4.4 Installation guidelines
- 4.5 Chemical resistance of the transponders
- 4.6 EMC Directives
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 Overview
- 5.2 RF310R with IQ-Sense interface
- 5.2.1 Features
- 5.2.2 Pin assignment of RF310R IQ-Sense interface
- 5.2.3 Display elements of the RF310R reader with IQ-Sense interface
- 5.2.4 Ensuring reliable data exchange
- 5.2.5 Metal-free area
- 5.2.6 Minimum distance between RF310R readers
- 5.2.7 Technical data for RF310R reader with IQ-Sense interface
- 5.2.8 FCC information
- 5.2.9 Ordering data of RF310R with IQ-Sense interface
- 5.2.10 Dimension drawing
System overview
3.2 RF300
SIMATIC RF300
18 System Manual, 09/2007, J31069 D0166-U001-A5-7618
3.2.3 RFID components and their function
RF300 system components
6HULDODV\QFKURQRXVLQWHUIDFH56
5)7 5)7
3RZHUDQGGDWDWUDQVPLVVLRQ0+]
5)5
,46HQVH
[,46HQVHIRU
(70
RQ6ZLWK
)&
3&LQWHUIDFH
WKLUGSDUW\3/&
$60IRU
6,0$7,&6
5)&IRU
(7SUR
$60IRU
(7;DQG
)&
$60IRU
352),%86
'39
5)7 5)7 5)7 5)7
5)5
5)5 5)5
$60bIRU
352),%86'3
'39
,46HQVH
LQWHUIDFH
5)5
5656
5)&IRU
352),1(7,2
Communication
modules
A communication module (interface module) is used to integrate the RF identification system in
PLC/automation systems.
Readers The reader (read/write device) ensures inductive communication, supplies power to the transponder,
and handles the connection to the various PLCs (e.g. SIMATIC S7) through the communication module
(e.g. ASM 475).
Transponder The transponder (data memory) stores all data relevant to the production process and is used, for
example, instead of barcode.
Conventions
The RF310R, RF340R and RF380R readers are equipped with an integral antenna, whereas
the RF350R reader is operated over an external antenna. In this system manual, the term
"Reader" is used throughout even where it is actually referring to the antenna of the reader.