User's Manual Part 1
Table Of Contents
- Titel
- SIMATIC Sensors RFID systems SIMATIC RF300
- Legal Information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 RF300 system planning
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader (with IQ-Sense interface) and transponder
- 4.1.9 Calculation example (IQ-Sense)
- 4.1.10 Communication between communication module, reader (with RS422 interface) and transponder
- 4.1.11 Calculation example (RS422)
- 4.2 Field data for transponders, readers and antennas
- 4.3 Relationship between the volume of data and the transponder speed
- 4.4 Installation guidelines
- 4.5 Chemical resistance of the transponders
- 4.6 EMC Directives
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 Overview
- 5.2 RF310R with IQ-Sense interface
- 5.2.1 Features
- 5.2.2 Pin assignment of RF310R IQ-Sense interface
- 5.2.3 Display elements of the RF310R reader with IQ-Sense interface
- 5.2.4 Ensuring reliable data exchange
- 5.2.5 Metal-free area
- 5.2.6 Minimum distance between RF310R readers
- 5.2.7 Technical data for RF310R reader with IQ-Sense interface
- 5.2.8 FCC information
- 5.2.9 Ordering data of RF310R with IQ-Sense interface
- 5.2.10 Dimension drawing
RF300 system planning
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
38 System Manual, 09/2007, J31069 D0166-U001-A5-7618
RF320T RF340T RF350T RF360T RF370T RF380T
RF340R
Length of the transmission
window (L
x
)
45 mm 60 mm 60 mm 70 mm 75 mm 85 mm
Width of the transmission
window (L
y
)
40 mm 45 mm 50 mm 60 mm 65 mm 75 mm
Operating distance (S
a
) 1...20 mm 2...25 mm 5...35 mm 8...40 mm 15...36 mm 15...47 mm
Limit distance (S
g
) 25 mm 35 mm 50 mm 60 mm 52 mm 55 mm
RF320T RF340T RF350T RF360T RF370T RF380T
RF350R / ANT1
Length of the transmission
window (L)
45 mm 60 mm 60 mm 70 mm 70 mm 88 mm
Operating distance (S
a
) 1...20 mm 2...25 mm 5...35 mm 8...40 mm 15...45 mm 15...53 mm
Limit distance (S
g
) 25 mm 35 mm 50 mm 60 mm 65 mm 65 mm
RF320T RF340T RF350T RF360T RF370T RF380T
RF350R / ANT18
Diameter of the
transmission window (L
d
)
10 mm 20 mm
Operating distance (S
a
) 1...8 mm 1...10 mm
Limit distance (S
g
) 10 mm 13 mm
Not yet released