Reduction of field data: Transponder and RF380R reader
Table 4-11 Reduction of field data by metal (in %): Transponder and RF380R
RF380R reader
Transponder
Without metal
on metal flush-mounted
in metal
(20 mm surround)
RF320T
Without metal 100 90 50
On metal; distance 20 mm 85 80 30
Flush-mounted in metal; distance
all-round 20 mm
35 30 20
RF340T
Without metal 100 95 60
on metal 93 90 52
Flush-mounted in metal;
distance all-round 20 mm
83 80 45
RF350T
Without metal 100 95 63
on metal 85 70 57
Flush-mounted in metal;
distance all-round 20 mm
70 60 46
RF360T
Without metal 100 98 60
On metal; distance 20 mm 85 75 70
Flush-mounted in metal;
distance all-round 20 mm
55 50 60
RF370T
Without metal 100 100 92
on metal 90 90 75
Flush-mounted in metal;
distance all-round 20 mm
70 65 60
RF380T
Without metal 100 93 55
on metal 80 75 50
Flush-mounted in metal; distance
all-round 40 mm