User's Manual Part 3

Transponders
6.7 RF380T
SIMATIC RF300
System Manual, 09/2007, J31069 D0166-U001-A5-7618
151
6.7.2.2 Metal-free area
Direct mounting of the RF380T on metal is permitted.
Mounting of RF380T on metal
Figure 6-18 Mounting of RF380T on metal
Flush-mounting of RF380T in metal:
D
Figure 6-19 RF380T flush-mounted in metal
The standard value for a is40 mm. At lower values, the field data change significantly,
resulting in a reduction in the range.