System Manual

Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
SIMATIC RF600
490 System Manual, 06/2019, J31069-D0171-U001-A22-7618
6
6GT2898
-
-
0
0ACx0
D
Design, dimensions and weight
s
s
Dimensions (L × W × H)
x Without plug x 140 × 85 × 35 mm
x With plug x 172.7 × 85 × 35 mm
Weight
720 g
T
Technical specifications of the input
Rated input voltage U
in
100 to 240 VAC
Input frequency f
in
50/60 Hz
Radio interference level
EN 55011/B
Switching frequency f
sw
approx. 70 kHz typ.
Connector type 7/8", 2-pin + PE
6 ... 8 mm
T
Technical specifications of the outputs
Output voltage tolerance U
out
U
out nom
+2 % / -1 %
at U
in
= 230 VAC, f = 50 Hz
Overvoltage protection
U
out nom
+20 % typ.
Noise U
LF
1 % U
out
at U
in
= min., BW: 1 MHz
Noise U
HF
2 % U
out
U
in
= min., BW: 20 MHz
Regulation
x Line regulation x 1.0%
at U
in
= min./max.
x Load regulation x 1.0%
at I
out
= 10...90...10%
Short-circuit current I
max
105 ... 130 % I
nom
at I
nom
= 3 A (+50 °C)
Settling time t
R
load variations < 5 ms
at I
out
= 10...90...10 %
Temperature coefficient ˢ 0.01 % / K
at T
A
= -25 °C ... +70 °C
Overload behavior P
over
Constant current
Short-circuit protection/
No-load response
Continuous/no-load stability
Derating 2 % / K
at T
A
> +50 °C ... +70 °C
Connector type M12, 4-pin
two sockets