RF600 system planning
4.8 Chemical resistance of the readers and transponders
SIMATIC RF600
88 System Manual, 06/2019, J31069-D0171-U001-A22-7618
S
Substance
T
Test conditions
E
Evaluation
C
Co
n
ncentration [%]
T
Temperature [°C]
Magnesium salts, w.
-
20
++++
1)
Methyl alcohol, w.
50 %
20
++++
Lactic acid, w. - 20 ++++
-
60
ഒ󰩜
Sodium carbonate, w. (soda)
-
20
++++
Sodium chloride, w.
-
20
++
Sodium hydroxide
10
20
++++
Nitrobenzene
-
20
++
1)
Phosphoric acid
10 %
20
ഒ󰩜
Propane
-
20
++++
Nitric acid
10 %
20
ഒ󰩜
Hydrochloric acid
10 %
20
ഒ󰩜
Sulfur dioxide
low
20
++
Sulfuric acid
25 %
20
ഒ󰩜
10 %
20
ഒ󰩜
Hydrogen sulfide
dry
20
++++
dry
60
ഒ󰩜
Carbon tetrachloride
1 ... 4
20
++++
1
)
Nothing specified for stainless steel
E
Explanation of the rating
++++
Resistant
+++
Practically resistant
++ Conditionally resistant
+
Less resistant
󰩜
Not resistant
conc.
Concentrated solution
w.
Water solution
c. s.
Cold saturated