Control of boiler temperature with 1-stage, 2-stage or modulating burner
(3-position or DC 0…10 V with feedback signal)
Acquisition of flue gas temperature, alarm when limit value is reached
Maximum and minimum limitation of boiler temperature
Maintained return temperature controlled via mixing valve (3-position or
DC 0…10 V), or with bypass pump
Control of a shutoff valve, with feedback signal
Selection of boiler operating mode
Limitation of burner’s minimum on time and of the return temperature
Protective boiler startup. Release of boiler, either automatically or manually
Flue gas measuring mode (boiler test mode, "Chimney sweep" function)
3 fault signal inputs, preconfigured for over-/underpressure and water shortage
in the boiler or in the hydraulic plant
Burner hours run counter and burner start counter
Acquisition and evaluation of heat requests (external setpoint, external DHW
request, and frost protection via the KNX bus)
Demand-compensated main control via mixing valve (3-position or DC 0…10 V),
or of the system pump in the main flow
Minimum and maximum limitation of main flow temperature
Shifting maximum limitation of main return temperature
Maximum limitation of main return temperature during DHW heating
Reception of heat meter pulses to limit the flow rate or the heat output
Acquisition and evaluation of heat requests (external setpoint, external DHW
request and frost protection via the KNX bus)
Demand-compensated main control via mixing valve (3-position or DC 0…10 V),
or of the main pump in the main flow
Minimum and maximum limitation of flow temperature
Shifting maximum limitation of return temperature
Maximum limitation of return temperature during DHW heating
Reception of heat meters pulses to limit the flow rate or the heat output
Several DHW variants available:
Storage tank charging via internal heat exchanger
Storage tank charging via external heat exchanger, optionally with maintained
secondary temperature
Storage tank charging with electric immersion heater
Direct DHW consumption via heat exchanger. Downstream consumer control
(control of DHW temperature at the tap)
Maximum limitation of return temperature
Proof of flow with flow switch
Reception of heat meter pulses to limit the flow rate or the heat output
"Legionella" function
7-day program with maximum 6 switching points per day
7-day program with maximum 6 switching points per day for circulating pump
Boiler temperature
control
Main control
Precontrol
DHW heating