User Manual
Changing the ON/OFF Times
The RWB2 is supplied with factory settings (See Factory Settings)
which will operate unless you change the set times:
If you wish to change the factory settings to your own times you can do
this easily:
No 1 tappet (orange) is the first ON during the 24 hour period
No 2 tappet (blue) is the first OFF during the 24 hour period
No 3 tappet (orange) is the second ON during the 24 hour period
No 4 tappet (blue) is the second OFF during the 24 hour period
To set the tappets to your own programme times hold the dial and slide
the relevant tappet and rotate it in either direction to your desired time,
then rotate dial through a full 24 hour rotation.
NB This should be carried out with the programmer connected and
power supply switched on to the backplate.
Power Failure
In the event of a mains power failure do not move the dial until power
has been restored. If accidentally the dial has been moved during a
power failure then rotate the dial through a full 24 hour rotation before
resetting to actual time.
Siemens Building Technologies Ltd.
Landis & Staefa Division
Hortonwood 30, Telford TF1 4ET
Tel: (01952) 677690
Fax: (01952) 602059
Help Desk Tel: (01952) 602048
Orders Tel: (01952) 602063