Operation Manual
51
Connecting the base station to PABX
Gigaset S680 / IM-NORD EN / A31008-M1901-R201-1-SM19 / pabx.fm / 1.10.08
Version 4, 16.09.2005
Connecting the base station
to PABX
The following settings are only necessary
when your PABX requires them; see the
PABX user guide.
You cannot send or receive SMS messages
on PABXs that do not support Calling Line
Identification.
Recall
The current setting is indicated by .
Setting recall
v ¢ Ð ¢ Base ¢ Add. Features
¢ Recall
s Select flashing time ( = on)
and press
§OK§.
a Press and hold (idle status).
Saving an access code
(outside line code)
Precondition: You may have to enter an
access code for external calls in your PABX,
e.g. "0".
v
¢ Ð ¢ Base ¢ Add. Features
¢ Access Code
~ Enter or change access code,
max. 3 digits.
¤ Save changes: (page 58).
If an access code has been saved,
u The access code is prefixed automati-
cally when you select from the follow-
ing lists: numbers of the SMS centres,
call history or answer machine list.
u The access code must be entered when
dialling manually and when manually
entering directory, emergency/quick
dial numbers and SMS centre numbers.
u If you copy the recipient's number from
the directory when sending an SMS,
you have to delete the access code.
u An existing access code is deleted using
X.
Setting pauses
Changing pause after line seizure
You can change the length of pause that is
inserted between pressing the talk key
c and sending the number.
v Open menu.
N 5 O L
Press keys.
~ Enter digit for the pause
length (1 = 1 sec.; 2 =3sec.;
3 = 7 sec.) and press
§OK§.
Changing the pause after the recall key
You can change the length of the pause if
your PABX requires this (refer to the user
guide for your PABX).
v Open menu.
N 5 O 2
Press keys.
~ Enter a digit for the length of
the pause (1 =800ms;
2 =1600ms; 3 =3200ms)
and press
§OK§.
‰
‰