Common Problem List for Single Connection User
The following situations can cause the communication to fail:
S Wrong baud rate: Correct the baud rate
S Wrong station address: Correct the station address
S PC/PPI cable set incorrectly: Check DIP switch settings on PC/PPI cable
S Wrong communication port on personal computer: Check comm port
S CPU in freeport mode (comm port under control of user program): Put CPU in
STOP mode
S Conflict with other masters: Disconnect the CPU from the network.