Installation manual

LITE SYSTEM INSTALLATION AND SUPERVISOR GUIDE 9.0 VER. 1
60
MAX LINES ALLOWED TO HOLD FOR ONE BOX: 2
WHILE IN QUEUE, SAY POSITION IN LINE? No
TRY EXTENSION 3 TIMES BEFORE GOING BACK TO CALLER
RESTRICTED DIGITS: [None]
Class of Service 7:
Set up with the class of service 0 options, but with SUPERVISOR STATUS? enabled.
Extension Length:
3 digits
Password Length:
4 digits
Default Passwords:
Equal the mailbox numbers
Mailbox 70:
Set up as the Supervisor mailbox with CLASS OF SERVICE: 7
Prototype mailbox 9994 (features automatically assigned to all mailboxes created):
TRANSFER TYPE: Wait for Ring
CLASS OF SERVICE: 0
To: X (signifies the mailbox number)
CURRENTLY ENABLED: Yes
TRANSFER SCHEDULE: Always
PASSWORD: X (signifies the mailbox number)
SEQUENCE TO TURN ON/OFF MESSAGE WAITING LAMP: (set by Integration program)
AFTER PLAYING GREETING: Wait for digit
2.7 Setting Up the System Using the Teleparameter
Feature
This section provides instructions on using the teleparameter feature to set up a new system at
a customer site or to later make modifications to the system. Using the teleparameter feature,
you can change the parameter values that affect system-wide setup information, box setups,
and VM.CFG file data by simply calling into the system. You simply log into supervisor
mailbox 70 over the telephone, select to modify system parameters, then, as prompted, enter