Switch User Manual

Product Characteristics
4.3 SCALANCE X208PRO
connector
Aging time
Aging time 5 minutes
Permitted Environmental Conditions / EMC
Operating temperature -20° C through +70° C
Storage/transport temperature -40° C through +80° C
Relative humidity in operation ‹ 95% (no condensation)
Operating altitude 2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
RF interference level EN 50081-2 Class A
Noise immunity EN 50082-2
Degree of protection IP65
Approvals
UL 60950 c-UL-us
CSA C22.2 No. 60950
c-Ul-us for hazardous locations UL 1604, UL 2279Pt.15
FM FM 3611
C-TICK AS/NZS 2064 (Class A).
CE EN 50081-2, EN 50082-2
ATEX Zone 2 EN50021
MTBF
MTBF 25.56 years
Construction
Dimensions (W x H x D) in mm 90 x 125 x 124
Weight in g 950
Installation options Wall mounting
DIN rail
ndard rail
Order Numbers
SCALANCE X208PRO 6GK5208-0CA00-2AA6
"Industrial Ethernet TP and Fiber Optic Networks"
manual
6GK1970-1BA10-0AA0
IE FC Stripping Tool 6GK1901-1GA00
IE FC blade cassettes 6GK1901-1GB00
IE FC TP standard cable 6XV1840 2AH10
IE FC TP trailing cable 6XV1840-3AH10
IE FC TP marine cable 6XV1840-4AH10
C-PLUG 6GK1 900-0AB00
Power M12 cable connector PRO 6GK1 907-0DC10-6AA3
Signaling contact M12 cable connector PRO 6GK1 908-0DC10-6AA3
Power supply PS791-1PRO 6GK5 791-1PS00-0AA6
Power cord M12 6GK1 907-0AF00-0AA0
S7-300 sta
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
4-24 Commissioning Manual, 1,