Switch User Manual

Diagnostics over Industrial Ethernet
6.2 Web Based Management (WBM)
Here, you enter the IP address of the SMTP server over which the E-mail is sent.
SMTP Server IP Port
The IP port over which the mail is sent. If necessary, you can change the default value 25 to
your own requirements.
"From" Field
Address of the sender of the E-mail.
6.2.4.15 The "Agent SNMP Configuration" WBM Menu
Agent SNMP Configuration - Configuration of SNMP for a SCALANCE X-200 Switch
On the SNMP Configuration page, you make basic settings for SNMP. For detailed settings
(traps, groups, users), there are separate menu items in WBM.
Figure 6-20 "Agent SNMP Configuration" Dialog
SNMP Read Only Check Box
Enables/disables write protection for SNMP variables.
Read Community String Text Box
Displays the user name for read access to SNMP variables.
Write Community String Text Box
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
6-24 Commissioning Manual, 1,