Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
5-26 Operating instructions, 09/2006, A5E00349864 Release 7
Here, you can set the Ethernet ports with which the switch is connected to the redundant
ring.
Note
By default, the following ring ports are set:
SCALANCE X208: TP port 1 and TP port 2
SCALANCE X204-2: FO port 5 and FO port 6
SCALANCE X206-1: TP port 1 and TP port 2
Note
SCALANCE X-200 devices can be operated in a redundant ring if one of the following
devices is used as a redundancy manager:
OSM ITP62 order number: 6GK1105-2AA10
OSM TP62 order number: 6GK1105-2AB10
OSM ITP53 order number: 6GK1105-2AD10
OSM BC08 order number: 6GK1105-4AA00
OSM TP22 order number: 6GK1105-2AE00
ESM TP40 order number: 6GK1105-3AC00
ESM TP80 order number: 6GK1105-3AB10
ESM ITP80 order number: 6GK1105-3AA10
SCALANCE X414-3E order number: 6GK5414-3FC00-2AA2