Operating instructions

Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
5-28 Operating instructions, 09/2006, A5E00349864 Release 7
Redundancy Manager
First Ring Port list box (relevant for IRT switches only)
Here, you select which ring port is the first or second ring port.
Second Ring Port list box (relevant for IRT switches only)
Here, you select which ring port is the first or second ring port.
Figure 5-19 X204IRT Ring Redundancy dialog (if the device is operating as a ring master)
Enable ring redundancy or Enable Ringports check box
This function is enabled and disabled here.
Redundancy manager mode list box
The redundancy manager is set here.
Static ring port list box
The port that is active in the ring is specified here.
Isolated ring port list box
The port that closes the ring but via which no communication takes place is specified here.
Redundancy manager state text box
This indicates whether or not the ring manager is enabled or disabled.
Number of state changes text box
This shows how often the redundancy manager switched to a different path due to an
interruption in the ring.