Operating instructions

Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Operating instructions, 09/2006, A5E00349864 Release 7
5-29
Maximum delay (ms) text box
This shows how much a test frame was delayed. (Test frames are placed on the ring to
detect interruptions in the ring.)
Note
The standby function always requires an activated redundancy client. If the standby
manager is "enabled", the following message appears if you attempt to disable ring
redundancy or to switch to redundancy manager:
Cannot disable "Redundancy" if "Standby Manager" is enabled.
Note
By default, the following ring ports are set:
SCALANCE X208, 206-1, 204IRT: TP port 1 and TP port 2
SCALANCE X204-2: FO port 5 and FO port 6
SCALANCE X202-2IRT, X200-4P IRT, X201-3P IRT, X202-2PIRT: FO port 3 and FO port 4
Note
SCALANCE X-200 devices (that are not IRT-compliant) can be operated in a redundant ring
if one of the following devices is used as a redundancy manager:
SCALANCE X204IRT order number: 6GK5204-0BA00-2BA3
SCALANCE X202-2IRT order number: 6GK5202-2BB00-2BA3
SCALANCE X202-2P IRT order number 6GK5202-2BH00-2BA3
OSM ITP62 order number: 6GK1105-2AA10
OSM TP62 order number: 6GK1105-2AB10
OSM ITP53 order number: 6GK1105-2AD10
OSM BC08 order number: 6GK1105-4AA00
OSM TP22 order number: 6GK1105-2AE00
ESM TP40 order number: 6GK1105-3AC00
ESM TP80 order number: 6GK1105-3AB10
ESM ITP80 order number: 6GK1105-3AA10
SCALANCE X414-3E order number: 6GK5414-3FC00-2AA2