Operating instructions

Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Operating instructions, 09/2006, A5E00349864 Release 7
5-31
The name of the standby connection is entered here; this must be identical to the name
entered for the standby partner.
Note
The standby manager always requires an activated redundancy client. If this is not activated,
the following error message is displayed:
"Cannot enable Standby manager if Redundancy is disabled and not in "Redundancy Client"
mode."
If the redundancy manager is enabled, standby mode is also not possible. In this case, the
following error message is displayed:
"Cannot enable Standby manager if Redundancy Manager is enabled."
Note
If two devices are linked by the standby function, the "Standby" function must be enabled on
both devices.