Operating instructions
Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Operating instructions, 09/2006, A5E00349864 Release 7
5-33
• NOT PRESENT
There is no C-PLUG inserted in the device.
C-PLUG Device Group text box
Indicates the SIMATIC NET product line that used the C-PLUG in previous operation.
C-PLUG Device Type text box
Indicates the device type within the product line that used the C-PLUG in previous operation.
Configuration Revision text box
Indicates the version of the configuration structure. This information relates to the
configuration options supported by the device. This does not relate to the actual hardware
configuration. This information does not change if you add or remove modules or extenders.
The information can, however, change if you update the firmware.
File System text box
Shows the type of C-PLUG file system.
File System Size text box
Shows the maximum storage capacity of the C-PLUG file system.
File System Usage text box
Shows the storage space being utilized in the C-PLUG file system.
C-PLUG Info String text box
Displays information on the device that used the C-PLUG in previous operation, for example
order number, type designation, version of hardware and software.
Modify C-PLUG list box, Modify button
If you are logged on as administrator, you can make settings here.
• Copy internal Configuration to C-PLUG and Restart
The configuration in the internal flash of the switch is copied to the C-PLUG and this is
followed by a restart.
Use case:
The device starts up with a C-PLUG inserted. This contains a configuration that differs
from the device or a configuration containing errors. If you have not made any changes to
the configuration after starting up the device, you can use this function to overwrite the
content of the C-PLUG with the original device configuration.
• Copy default Configuration to C-PLUG and Restart
This stores the configuration with all factory default values on the C-PLUG. This is
followed by a restart during which devices of the SCALANCE X-200 product line restart
with these default values.
• Clean C-PLUG (Low Level Format, Configuration lost)
Deletes all data from the C-PLUG and triggers low-level formatting. This is not followed
by an automatic restart and the device displays an error. You can clear this error status
by restarting or removing the C-PLUG.
Your selection is then adopted when you click "Modify".