Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Operating instructions, 09/2006, A5E00349864 Release 7
5-41
5.2.6.20 The "Agent Time Client Configuration" WBM menu
Agent Time Client Configuration
This dialog is used to configure the time protocols.
Figure 5-27 Agent Time Client Configuration dialog
Current System Time text box
Either the time since the last restart or the current time is displayed here.
If the time is received from a "non-time server", the text "not synchronized" is displayed.
Enable Time Client check box
The time function can be enabled and disabled here.
Time Client Type list box
You can choose from four different protocol types here:
• SNTP Poll
If you choose this protocol type, you have to define further settings:
Time server: The IP address of the server is specified here.
Port: The communication port to the SNTP server is entered here.
Init poll interval: Indicates the wait time in milliseconds until the first poll is sent to the
server.
Poll interval: Indicates the interval in seconds in which the time is updated.
• SNTP Listen