Operating instructions
Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
5-50 Operating instructions, 09/2006, A5E00349864 Release 7
512-1023 information box
Displays the number of packets with a length of 512-1023 bytes.
1024-1518 information box
Displays the number of packets with a length of 1024-1518 bytes.
Figure 5-35 "Statistics Packet Size Graphic" dialog (graphic view)
5.2.6.28 The "Statistics Packet Type" WBM menu
Packet Type Statistics - received packets sorted according to type
The Statistics Packet Type page displays how many frames of the type unicast, multicast,
and broadcast were received at each port.
If you click the Reset Counters button, you reset the counters for all ports.
If you click on an entry in the Port column, the Statistics Packet Type Graphic is displayed for
the selected port. You then see a graphical representation of the counter value.