Operating instructions

Configuration / diagnostics using remote mechanisms
5.2 Configuration with Web Based Management (WBM)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
5-58 Operating instructions, 09/2006, A5E00349864 Release 7
Table 5-2 Variables in the Interface directory
Variable Access rights Description
ifNumber Read only The number of different interfaces available in the
component.
Possible values: 4 - 8
ifDescr Read only A description and possibly additional information for a port.
Possible value: string with a maximum of 255 characters
ifType Read only The value ethernet-csmacd(6) or optical(65) is entered for
SCALANCE X-200.
ifSpeed Read only Data transfer rate of the Ethernet port in bits per second.
SCALANCE X-200 devices: either 10 Mbps or 100 Mbps
ifOperStatus Read only The current operating status of the Ethernet port. The
following values are possible: ● up(1) ● down(2)
ifLastChange Read only Length of time for which the selected port has been
operating in the current status. The value is shown in
hundredths of a second.
ifInErrors Read only Number of received packages that were not forwarded to
higher protocol layers because of an error.
ifOutErrors Read only Number of packages that were not sent because of an
error.
Port Indexes
The interface index must be used for port designations. The following table shows how the
interface indexes are assigned to the ports.
Interface Index Port
1 Port 1
2 Port 2
3 Port 3
4 Port 4
5 Port 5
6 Port 6
7 Port 7
8 Port 8