Operating instructions
PROFINET IO functionality
7.1 Configuring with PROFINET IO
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
7-6 Operating instructions, 09/2006, A5E00349864 Release 7
Figure 7-6 Assign Device Name PNIO dialog
If you use more than one IO device, the Assign Device Names dialog also displays more
than one IO device. In this case, you should compare the MAC address of the device with
the indicated MAC address and select the proper IO device. You can also check the
assignment visually with the "Flashing On/Off" button (all the LEDs of the selected
SCALANCE flash).
1. Click on the Assign Name button in the Device Names dialog box. The device name is
stored permanently on the SCALANCE.
After assigning the name, the device name you assigned appears in the dialog box.
1. Download the hardware configuration to the CPU317-2PN/DP.
2. Select PLC > Download to Module