Operating instructions
Product properties
3.6 SCALANCE X106-1
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
3-14 Operating instructions, 09/2006, A5E00349864 Release 7
3.6.2 SCALANCE X106-1 TP ports
Connector pinout
On the SCALANCE X106-1, the TP ports are implemented as RJ-45 jacks with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Figure 3-6 RJ-45 jack
Table 3-9 Pin assignment
Pin number Assignment
Pin 8 n. c.
Pin 7 n. c.
Pin 6 TD-
Pin 5 n. c.
Pin 4 n. c.
Pin 3 TD+
Pin 2 RD-
Pin 1 RD+
Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP
port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.