Operating instructions
Product properties
3.21 Technical specifications
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
3-70 Operating instructions, 09/2006, A5E00349864 Release 7
Device type
SCALANCE
Attachment of end devices
or network components
over twisted pair
Connecting end devices or
network components over
fiber-optic
Connector for power
supply
Connector for
signaling contact
X200-4P IRT 4 SC RJ sockets
(100 Mbps, full duplex to
100BaseFX)
1x4-pin plug-in terminal
block
1x2-pin plug-in terminal
block
Table 3-21 Electrical data
Device type
SCALANCE
Power supply
2 x 24 V DC
(18-32 V DC)
Safety extra-low voltage
(SELV)
Power loss at
24 V DC
Current consumption
at rated voltage
Overcurrent protection at
input
PTC resettable fuse
(0.6 A / 60 V)
X108 + 3.36 W 140 mA +
X104-2 + 4.2 W 175 mA +
X106-1 + 3.6 W 150 mA +
X208 + 4.4 W 185 mA +
X208PRO + 4.4 W 185 mA +
X204-2 + 5.16 W 215 mA +
X206-1 + 4.8 W 200 mA +
X204-2 LD + 5.16 W 215 mA +
X206-1 LD + 4.8 W 200 mA +
X202-2IRT + 6.0 W 300 mA +
X204IRT + 4.8 W 200 mA +
X202-2P IRT + 7.2 W 300 mA PTC resettable fuse
(1.1 A / 33 V)
X201-3P IRT + 8.4 W 350 mA PTC resettable fuse
(1.1 A / 33 V)
X200-4P IRT + 9.6 W 400 mA PTC resettable fuse
(1.1 A / 33 V)