Operating instructions

Product properties
3.21 Technical specifications
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
3-72 Operating instructions, 09/2006, A5E00349864 Release 7
Table 3-24 Permitted cable lengths (fiber-optic)
Device type
SCALANCE
1 - 50 m
980/1000 plastic
optical fiber (POF)
1 - 100 m
200/230 polymer cladded
fiber (PCF)
6 dB max. permitted FO
cable attenuation with 3 dB
link power margin
0 - 3000 m
glass FOC
62.5/125 µm or 50/125 µm
glass fiber;
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted FO
cable attenuation with 3 dB
link power margin
0 - 26000 m
glass FOC
10/125 µm single mode fiber; 0.5
dB/km at 1300 nm;
13 dB max. permitted FO cable
attenuation with 2 dB link power
margin
X108 - - - -
X104-2 - - + -
X106-1 - - + -
X208 - - - -
X208PRO - - - -
X204-2 - - + -
X206-1 - - + -
X204-2 LD - - - +
X206-1 LD - - - +
X202-2IRT - - + -
X204IRT - - - -
X202-2P IRT + + - -
X201-3P IRT + + - -
X200-4P IRT + + - -
Table 3-25 Aging time/ MTBF
Device type
SCALANCE
Aging time
X108 30 seconds
X104-2 30 seconds
X106-1 30 seconds
X208 30 seconds
X208PRO 30 seconds
X204-2 30 seconds
X206-1 30 seconds
X204-2 LD 30 seconds
X206-1 LD 30 seconds
X202-2IRT 30 seconds
1)
X204IRT 30 seconds
1)
X202-2P IRT 30 seconds
1)
X201-3P IRT 30 seconds
1)
X200-4P IRT 30 seconds
1)
1
supports fast learning: Quick recognition of MAC addresses on the device that change
during operation (for example, when an end node is reconnected).