Operating instructions

Installation and maintenance
4.1 Installation
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
4-4 Operating instructions, 09/2006, A5E00349864 Release 7
Figure 4-3 Installation of a SCALANCE X-100 and/or X-200 on a SIMATIC S7-300 standard rail
Uninstalling
To remove the Industrial Ethernet switches of the SCALANCE X-100 and X-200 product
lines from the SIMATIC S7-300 standard rail:
1. First disconnect all connected cables.
2. Loosen the screws on the underside of the S7 standard rail and lift the device away from
the rail.
4.1.3 Wall mounting
Wall mounting
1. For wall mounting, use suitable mounting fittings for the wall
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws
3.5 mm diameter and 40 mm long).
2. Connect the electrical cable connecting cables.
3. Fit the connectors for the signaling contact.
4. Insert the terminal blocks or M12 cable connectors into the sockets on the device.
For more exact dimensions, please refer to the section "Dimension drawings".
Note
The wall mounting must be capable of supporting at least four times the weight of the device.