User's Manual

Product Characteristics
4.3 SCALANCE X208PRO
Port status indicator (green/yellow LEDs)
The status of the ports is indicated by eight two-color LEDs:
Status Meaning
Port 1 through 8 LED lit green TP link exists, no data reception
Port 1 through 8 LED lit yellow TP link exists, data received at TP port
Device startup, the LED is lit for approx. 6s.
Ports 1 through 8 LED flash yellow Setting or display of the fault mask
Port 1 through 8 LED flashes green The "Show Location" function was activated over Ethernet (e.g.
PST tool).
LED Display during Startup
Following startup, the following LEDs light up in the following order:
Power LEDs (green) light up immediately after turning on the power.
Port LEDs (yellow) light up for approx. 6 s, the red LED is off.
Port LEDs go off, the red LED is lit for approx. 20 s.
After the port LEDs go off, the correct link status is displayed after approx. 2 s.
The device is now ready for operation.
4.3.8 SCALANCE X208PRO Technical Specifications
Technical Specifications of the SCALANCE X208PRO
Ports
Attachment of DTEs or network components over
twisted pair
8 x RJ-45 sockets with MDI-X pinning 10/100
Mbps (half/ full duplex)
Connector for power supply 2 x 4-pin M12 port (a-coded)
Connector for signaling contact 5-pin M12 port (b-coded)
Electrical Data
Power supply 2 x 24 V DC
(18 through 32 V DC)
Power loss at DC 24 V 4.4 W
Current consumption at rated voltage 185 mA
Overvoltage protection at input PTC resetable fuse (0.6 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 -100 m
0 - 85 m
IE FC standard cable with IP67 push pull
connector
IE FC marine/trailing cable with IP 67 push pull
safety extra-low voltage (SELV)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,