Operating Instructions

Descriptions of Parameter Settings
Descriptions of Parameter Settings
112 | 443
Settings
Functions
Descriptions
81
Simple positioning zero point
position signal input
Use this function as the trigger terminal for simple positioning with Pr.02-78Pr.02-80.
This function is just a simple positioning, so you must verify the positioning accuracy.
Refer to Pr.02-80 for details.
82
OOB loading balance detection
You can use the OOB (Out Of Balance Detection) function with the PLC program in the
washing machine system. ON: it receives the Δθ value according to Pr.07-46 (OOB
Sampling Time) and Pr.07-47 (Number of OOB Sampling Times). The PLC or the host
controller determines the motor’s speed according to this Δθ value (Pr.07-48).
83
Multi-motor (IM) selection bit 0
ON: parameters can be changed
Example: MI1 = 83, MI2 = 84
MI1
MI2
Motor
Selection
Related Motor Parameter
Max. Operation
Frequency
V/F Curve
Parameters
OFF
OFF
Motor 1
Pr.01-00
Pr.01-0101-08
ON
OFF
Motor 2
Pr.01-52
Pr.01-3501-42
OFF
ON
Motor 3
Pr.01-53
Pr.01-5401-61
ON
ON
Motor 4
Pr.01-62
Pr.01-6301-70
84
Multi-motor (IM) selection bit 1
Pr.
Explanation
Settings
Default
02-09
UP / DOWN key mode
0: UP / DOWN by the acceleration / deceleration time
1: UP / DOWN constant speed (Pr.02-10)
2: Pulse signal (Pr.02-10)
3: External terminals UP / DOWN mode
4: External terminals UP / DOWN mode (Pr.02-10)
0
02-10
Constant speed, acceleration /
deceleration speed of the
UP/DOWN Key
0.0011.000 Hz/ms
0.001