Operating Instructions
Specifications
575V Models
17 | 443
575V Models
Frame
A
B
C
D
Product Number
RT001X-53N
RT002X-53N
RT003X-53N
RT005X-53N
RT0075-53N
RT010X-53N
Applicable Motor Output [kW]
0.75
1.5
2.2
3.7
5.5
7.5
Applicable Motor Output [HP]
1
2
3
5
7.5
10
Outp
ut
Heavy
Duty
Rated Output Capacity [kVA]
1.7
3
4.2
6.6
9.9
12.2
Rated Output Current [A]
1.7
3
4.2
6.6
9.9
12.2
Carrier Frequency [kHz]
2 to 15 (Default: 4)
Normal
Duty
Rated Output Capacity [kVA]
2.1
3.6
5
8
11.5
15
Rated Output Current [A]
2.1
3.6
5
8
11.5
15
Carrier Frequency [kHz]
2 to 15 (Default: 4)
Input
Rated
Input
Current
[A]
Heavy Duty
2
3.5
4.9
7.7
11.5
14.2
Normal Duty
2.4
4.2
5.8
9.3
13.4
17.5
Rated Voltage/Frequency
Three-phase 500 to 600 Vac (-15 to 10%), 50/60 Hz
Mains Input Voltage Range [Vac]
425 to 660
Mains Frequency Range [Hz]
47 to 63
Weight lbs (kg)
1.87 (0.85)
1.92 (0.87)
2.60 (1.18)
2.84 (1.29)
4.50 (2.04)
Cooling Method
Convective
cooling
Fan cooling
EMC Filter
Optional
IP Rating
IP20
Table 7: 575V models three-phase.
General Specifications
Control
Characteristics
Control Method
V/F, SVC, FOC
Applicable Motor
IM (Induction Motor), Simple PM motor control (IPM and SPM)
Starting Torque
[Note 1]
150%/3 Hz
100%/(motor rated frequency/20)
200%/0.5 Hz
(V/F, SVC control for IM, heavy duty, rated)
(SVC control for PM, heavy duty, rated)
(FOC control for IM, heavy duty, rated)
Speed Control
Range [Note 1]
1: 50 (V/F, SVC control for IM, heavy duty, rated)
1: 20 (SVC control for PM, heavy duty, rated)
1: 100 (FOC control for IM, heavy duty, rated)
Max. Output
Frequency
0.00–599.00 Hz
Overload Capacity
Normal duty:
120% of rated current can endure for 1 minute during every 5 minutes
150% of rated current can endure for 3 seconds during every 30 seconds.
Heavy duty (default):
150% of rated current can endure for 1 minute during every 5 minutes
200% of rated current can endure for 3 seconds during every 30 seconds
Frequency Setting
0 to 10V / -10 to 10V